cGLP Accredited Laboratory • 21 CFR Part 11 Integrity • Vapi NH-48 Hub
Analytical Testing Laboratories In Vapi, Gujarat

Analytical Testing Laboratory in Vapi
Precision Testing for Better Decisions.

Satvam Research is a premier cGLP & 21 CFR Part 11 compliant analytical testing laboratory in Vapi, Gujarat. Operating an 8,500 sq. ft. modern facility on NH-48 GIDC, we deliver reliable, audit-ready testing for pharmaceuticals, APIs, IS 10500 water testing, chemical intermediates, cosmetics, and environmental monitoring.

Select a Testing Platform to View Live Specs:
Validated Testing Protocol

HPLC Assay & Impurities

Method Specs
LIVE ACQUISITION: Shimadzu DATA STREAM21 CFR PART 11 SECURE
Retention Time: 4.82 min
USP Tailing: 1.04
Theoretical Plates: 8,420
Primary SystemShimadzu Prominence LC-20AD (UV/PDA)
Monograph ReferenceIP, BP, USP, EP & JP Monographs
Standard TAT3 – 5 Days (48h Urgent Available)

High-precision chromatographic assay, related substances profiling, and ICH Q2(R1) method validation with automated electronic signatures.

ISO/IEC 17025 Aligned
cGLP Quality
21 CFR Part 11
ALCOA+ Data Integrity
Satvam Research Modern HPLC Laboratory
21 CFR Part 11 Active
99.82% Assay
Monograph Pass
ICH Q2 / Assay
cGLP Audit-Ready Release
Dual QA Electronic Verification
Book TAT
8,500
sq. ft. Testing Facility

Environmentally controlled cGLP laboratories with separate instrument, wet chemistry & cleanroom zones.

100+
Testing Parameters

Comprehensive testing suite spanning chromatography, spectroscopy, wet chemistry & microbial assay.

6 Sectors
Pharma • Cosmetics • Water

Chemicals, intermediates, medical devices & packaging, and herbal formulations testing.

Vapi, GIDC
NH-48 Strategic Hub

Direct national highway logistics serving Mumbai, Surat, Bharuch, Ahmedabad & global clients.

HOW IT WORKS

Your testing journey in 3 simple steps.

Get started in minutes and take complete control of your analytical release, no complicated bureaucracy or guesswork required.

01

Log Your Samples

Submit test requests or schedule same-day courier pickup. Samples receive barcoded chain-of-custody tracking in seconds.

02

Get Calibrated Testing

Samples are analyzed on qualified Shimadzu HPLC, GC, and Lab India ICP-OES under full 21 CFR Part 11 electronic audit controls.

03

Hit Your Release Goals

Receive audit-ready, digitally signed Certificates of Analysis. Fast-track commercial batch release and regulatory approvals.

Testing Services

Core Testing Capabilities

Each service is configured with dedicated protocols, 21 CFR Part 11 data integrity, and qualified instrumentation

ICH Q2(R1) & FDA Aligned

Method Validation & Lifecycle

Satvam Research provides comprehensive analytical method development, validation, verification, and transfer for pharmaceuticals, APIs,...

Custom method design and chromatographic parameter optimization
Full validation parameter matrix conforming to ICH Q2(R1)
Method verification of compendial pharmacopeial monographs (USP, EP, BP, IP)
TAT: 10 DaysFull Method Specs
ICH Q3D & USP <232>/<233>

Elemental Impurities (ICH Q3D)

Satvam Research provides trace elemental impurities screening conforming to ICH Q3D, USP <232>/<233>, and FDA guidelines. Utilizing our...

Screening and quantitative determination of Class 1 elements: As, Cd, Pb, Hg
Quantitation of Class 2A elements: Co, Ni, V
Quantitation of Class 2B elements: Tl, Au, Pd, Ir, Os, Rh, Ru, Se, Ag, Pt
ICH Q1A(R2) & Q1B Photostability

Stability & Shelf-Life Studies

Satvam Research provides accelerated, intermediate, and real-time stability testing for pharmaceutical formulations, APIs, cosmetics, a...

Accelerated conditions: 40°C ± 2°C / 75% RH ± 5% RH
Intermediate conditions: 30°C ± 2°C / 65% RH ± 5% RH
Real-time conditions: 25°C ± 2°C / 60% RH ± 5% RH (Zone II) and 30°C ± 2°C / 75% RH (Zone IVb)
TAT: Pull-point DaysFull Method Specs
ICH Q3C & USP <467>

Residual Solvent Analysis (GC/GCHS)

Satvam Research performs high-sensitivity residual solvent profiling and volatile organic analysis complying with ICH Q3C and USP <467>...

Class 1 Solvents: Benzene, Carbon tetrachloride, 1,2-Dichloroethane, 1,1-Dichloroethene
Class 2 Solvents: Acetonitrile, Chlorobenzene, Chloroform, Hexane, Methanol, Pyridine, Toluene
Class 3 Solvents: Acetone, Ethanol, Ethyl acetate, IPA, MEK
ICH Q3A/B & Compendial

Related Substances & Assay (HPLC)

Satvam Research provides high-resolution chromatographic assay and related substances determination for Active Pharmaceutical Ingredien...

Finished dosage form assay (tablets, capsules, syrups, topicals, injectables)
Related substances and chromatographic purity profiling
Impurity peak identification via PDA spectral library matching
IP, BP, USP, EP, JP

Compendial Monograph Testing

Satvam Research conducts complete compendial monograph evaluation as per Indian Pharmacopoeia (IP), British Pharmacopoeia (BP), United ...

Identification tests: FTIR fingerprinting, UV absorption, colorimetric reactions
Physical constants: Melting point, boiling range, optical rotation, refractive index
Assay and potency: Potentiometric titration, HPLC, GC, non-aqueous titration
Hardware Specifications

Advanced Analytical Instrumentation

Top-tier chromatography, spectroscopy, and physical characterization systems from global market leaders

Particle Size Analyzer - Mastersizer 3000+ Ultra
Physical Characterization
Malvern Panalytical

Particle Size Analyzer

Mastersizer 3000+ Ultra

Laser diffraction-driven particle size distribution (PSD) metrics with wet and dry dispersion modules for sub-micron to millimeter particle characterization.

Sub-micron to 3500 µm range
High-speed laser diffraction
HPLC Systems - Prominence LC-2080C
Chromatography
Shimadzu

HPLC Systems

Prominence LC-2080C

Equipped with UV, PDA, and Refractive Index (RID) detectors for chromatographic purity, related substances, organic impurities, and assay of raw materials and finished goods.

UV, PDA & RID detectors
21 CFR Part 11 software
GC & Headspace (GCHS) - Nexis GC-2050 & GC-2014C
Chromatography
Shimadzu

GC & Headspace (GCHS)

Nexis GC-2050 & GC-2014C

High-sensitivity FID and TCD detection for volatile organic analysis, residual solvent profiling (including Residual ETO, Ethylene Glycol), and gas purity determination.

FID & TCD detectors
Automated Headspace Sampler
ICP-OES - ICP 5000DV
Elemental Analysis
Lab India

ICP-OES

ICP 5000DV

Comprehensive elemental analysis and dual-view plasma spectroscopy for trace heavy metal monitoring and elemental impurities evolution satisfying ICH Q3D & FDA guidelines.

Dual-view plasma
Sub-ppb trace detection
Microwave Digestion System - MARS 6
Sample Preparation
CEM Corporation

Microwave Digestion System

MARS 6

Closed-vessel high-pressure microwave sample preparation supporting total recovery, precise sample breakdown, and complex matrix digestion for downstream ICP-OES profiling.

High-throughput closed vessels
Precise temperature & pressure control
FTIR Spectrophotometer - IRSpirit-X
Spectroscopy
Shimadzu

FTIR Spectrophotometer

IRSpirit-X

High-resolution Fourier-transform infrared spectroscopy for structural identification, raw material fingerprinting, and polymer/compound verification.

High S/N ratio
ATR & transmission modes
Strategic Hub

Vapi Logistics Hub on NH 48

Positioned in South Gujarat's pharmaceutical heartland with direct highway logistics

Direct Access to NH 48

Strategic Highway Connectivity

Situated directly on National Highway 48, providing seamless logistics and same-day sample pickup across Mumbai, Surat, Bharuch, Vadodara, and Ahmedabad.

Heart of GIDC South Gujarat

Proximity to Mega Industrial Hubs

Directly connected to Vapi GIDC, Sarigam GIDC, Umbergaon GIDC, Pardi GIDC, Gundlav GIDC, Daman Industrial Area, and Silvassa Industrial Area—one of India's largest industrial corridors.

Seasoned Technical Team

Trained Scientific Talent Pool

Availability of qualified pharmaceutical chemists, microbiologists, and regulatory experts experienced with USFDA, WHO, and EU compliance workflows.

Uninterrupted Testing Operations

Robust Industrial Infrastructure

Continuous power, high-grade water, secure sample warehousing, and cold-chain storage facilities supporting strict turnaround times.

Frequently Asked Questions

Questions About Testing & Compliance

Which is the premier analytical testing laboratory in Vapi for pharmaceutical, chemical, and water testing?

Satvam Research Private Limited is widely recognized among the premier analytical testing laboratories in Vapi, Gujarat. Located on NH-48 GIDC Vapi, our 8,500 sq. ft. cGLP and 21 CFR Part 11 compliant facility provides full-scale testing for APIs, finished dosage forms, IS 10500 drinking and effluent water, environmental stack/ambient air, agrochemicals, and food products.

What capabilities distinguish Satvam Research from other testing labs in Vapi?

Unlike conventional testing labs in Vapi, Satvam Research combines fully computerized 21 CFR Part 11 data integrity with advanced instrumentation: Shimadzu HPLC Prominence-i (with PDA), Shimadzu Brevis GC-2050 (Headspace HS-20 NX), LabIndia Dual-View ICP-OES (ICP-5000DV), Malvern Mastersizer 3000, and CEM MARS 6 Microwave Digestion, backed by dual-level QA sign-offs and rapid 48-hour rush TAT.

Where is Satvam Research located and what industries are served in Vapi GIDC?

Satvam Research operates an 8,500 sq. ft. modern testing laboratory at 3rd Floor, Nepal Complex, N.H. 48, GIDC, Vapi, Dist. Valsad, Gujarat - 396 195. We serve Pharmaceutical, Cosmetics, Chemical, Intermediate, Water, Medical Devices, Agrochemical, and Food industries across Vapi, Daman, Silvassa, and Gujarat.

How does Satvam Research ensure 21 CFR Part 11 and data integrity?

Our analytical workstations (Shimadzu HPLC, Shimadzu GC, Lab India ICP-OES) operate under computerized chromatography software featuring multi-tiered user access controls, unalterable electronic audit trails, automated password expiration, and secure local server archiving.

What pharmacopoeias and guidelines are supported?

We execute testing according to Indian Pharmacopoeia (IP), British Pharmacopoeia (BP), United States Pharmacopeia (USP), European Pharmacopoeia (EP), Japanese Pharmacopoeia (JP), Bureau of Indian Standards (IS: 10500:2012 for water), and ICH Q1A/B, Q2(R1), and Q3D guidelines.

How can clients submit samples from Mumbai, Surat, or nearby industrial areas?

Situated directly on National Highway 48, our logistics team coordinates same-day sample pickup across Vapi GIDC, Sarigam, Umbergaon, Pardi, Gundlav, Daman, and Silvassa, and receives cold-chain shipments seamlessly from Mumbai, Surat, Bharuch, and Ahmedabad.